BW200型往复泵曲轴磨损原因分析及解决措施
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

P634.3+2;TH321

基金项目:


Cause Analysis on Crankshaft Wear of BW200 Reciprocating Pump and the Solution Measures
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    建立齿轮传动往复泵的曲柄连杆机构曲轴空间力系,对曲轴曲柄销轴进行受力分析。通过加装平衡条平衡旋转惯性力和改变进水管接口位置试验,找出了液力端进排水流道尺寸的改变是BW200型泵的工作腔液体产生水击的原因,解决了泵温升高和曲轴曲柄销磨损问题。可用于齿轮传动往复泵的曲柄连杆机构曲轴受力分析和计算,解决泥浆泵的类似问题。

    Abstract:

    The crankshaft space force system of crank and connecting rod mechanism of gear transmission reciprocating pump was established for mechanical analysis on crankshaft crank pin shaft. Through adding balance strip to have rotating inertia force equilibrium and testing to change the interface position of intake pipe, the size change of intake and drainage channels at hydraulic end was found out to be caused by the water attack from the liquid in BW200 pump chamber, and the pump temperature increasing and crankshaft crank pin wearing were solved.

    参考文献
    相似文献
    引证文献
引用本文

周利文,李宗义,王安平,等. BW200型往复泵曲轴磨损原因分析及解决措施[J].钻探工程,2011,38(9):74-77.
ZHOU Li-wen, LI Zong-yi, WANG An-ping, et al. Cause Analysis on Crankshaft Wear of BW200 Reciprocating Pump and the Solution Measures[J]. Drilling Engineering, 2011,38(9):74-77.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2011-01-31
  • 最后修改日期:2011-09-16
  • 录用日期:2011-03-31
  • 在线发布日期: 2011-09-28
  • 出版日期: