Application Study on Wall Protection Technology with PVC Pipe in Gas Drainage Hole in Soft Seams
DOI:
Author:
Affiliation:

Xi’an Research Institute of China Coal Technology & Engineering Group Corp.,Zhaozhuang Coal Co., Ltd., Jincheng Anthracite Mining Group,Zhaozhuang Coal Co., Ltd., Jincheng Anthracite Mining Group,Xi’an Research Institute of China Coal Technology & Engineering Group Corp.,Xi’an Research Institute of China Coal Technology & Engineering Group Corp.,Xi’an Research Institute of China Coal Technology & Engineering Group Corp.

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Geological structure is complex with soft seams and poor permeability in Zhaozhuang coal mine of Shanxi. Wall collapse of gas drainage hole caused by unstability leads to gas drainage channel blocking, low extraction rate and poor drainage effect. By the technology that drill pipe is kept at the completion of drilling construction and in which gas extraction screen liner is lowered to protect the wall, gas drainage channel can be formed after drill pipe is lifted. The application results show that the pipe lowering efficiency is largely improved comparing with that of traditional drill casing technology. The pipe length is up to more than 98% of the hole depth, which is helpful to improve the efficiency of gas drainage and has great significance for coal mine safety.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:March 11,2014
  • Revised:March 11,2014
  • Adopted:June 14,2014
  • Online: July 28,2014
  • Published: